<?xml version="1.0" encoding="UTF-8"?><rss version="2.0" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Irrigation Flow Guide: Smart Flow Meters and Controllers</title><description>Plain guides to smart irrigation flow meters and controllers, built from published official documentation.</description><link>https://irrigationflowguide.com/</link><language>en</language><atom:link href="https://irrigationflowguide.com/rss.xml" rel="self" type="application/rss+xml"/><item><title>Hunter HC Flow Meter, Rain Bird FG100, EveryDrop Comparison</title><link>https://irrigationflowguide.com/posts/hunter-hc-flow-meter-rain-bird-fg100-everydrop/</link><guid isPermaLink="true">https://irrigationflowguide.com/posts/hunter-hc-flow-meter-rain-bird-fg100-everydrop/</guid><description>Compare the Hunter HC Flow Meter, Rain Bird FG100, and wired EveryDrop 1004-EX by controller fit, flow limits, fittings, and monitoring setup.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Start with the controller you already have. Choose the Hunter HC Flow Meter for a compatible Hydrawise controller, the Rain Bird FG100 for an ESP-ME3, or the wired EveryDrop 1004-EX for a Rachio Gen 2 or Rachio 3. Then check the flow of your slowest and fastest zones and the space available around the meter. &lt;a href=&quot;https://shop.hunterirrigation.com/products/hunter-hc-flow-meter-for-hydrawise-controllers&quot;&gt;Hunter&lt;/a&gt;, &lt;a href=&quot;https://www.rainbird.com/products/fg100&quot;&gt;Rain Bird&lt;/a&gt;, &lt;a href=&quot;https://everydropmeters.com/pages/frequently-asked-questions&quot;&gt;EveryDrop&lt;/a&gt;, &lt;a href=&quot;https://rachio.com/products/everydrop-flow-meter&quot;&gt;Rachio&lt;/a&gt;.&lt;/p&gt;
&lt;h2&gt;Controller fit and published flow limits&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Meter&lt;/th&gt;
&lt;th&gt;Controller pairing&lt;/th&gt;
&lt;th&gt;1-inch connection&lt;/th&gt;
&lt;th&gt;Published flow in gallons per minute (GPM)&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Hunter HC-100-FLOW&lt;/td&gt;
&lt;td&gt;Hydrawise-enabled HC, HPC, Pro-HC, or HCC&lt;/td&gt;
&lt;td&gt;Male NPT&lt;/td&gt;
&lt;td&gt;0.3 to 30 recommended range. Hydrawise lists a maximum of 34 GPM. &lt;a href=&quot;https://shop.hunterirrigation.com/products/hunter-hc-flow-meter-for-hydrawise-controllers&quot;&gt;Hunter specifications&lt;/a&gt;, &lt;a href=&quot;https://www.hydrawise.com/content/hydrawise-controllers-and-hardware&quot;&gt;Hydrawise hardware&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Rain Bird FG100&lt;/td&gt;
&lt;td&gt;ESP-ME3&lt;/td&gt;
&lt;td&gt;NPT (A83926), slip (A83927), or BSP (A83928)&lt;/td&gt;
&lt;td&gt;3 minimum, 25 recommended maximum, 35 maximum. &lt;a href=&quot;https://www.rainbird.com/products/fg100&quot;&gt;Rain Bird specifications&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;EveryDrop 1004-EX, wired&lt;/td&gt;
&lt;td&gt;Rachio Gen 2 or Rachio 3&lt;/td&gt;
&lt;td&gt;PVC unions included&lt;/td&gt;
&lt;td&gt;EveryDrop lists a maximum of 30 GPM. &lt;a href=&quot;https://everydropmeters.com/pages/frequently-asked-questions&quot;&gt;EveryDrop FAQ&lt;/a&gt;, &lt;a href=&quot;https://rachio.com/products/everydrop-flow-meter&quot;&gt;Rachio compatibility&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;If you have a low-flow drip zone, check its expected flow against the published minimum before choosing a meter. A zone below 3 GPM falls below the FG100 minimum. Rain Bird lets you disable flow sensing for that station on the ESP-ME3. For the fastest zones, use the recommended maximum where Hunter or Rain Bird gives one. &lt;a href=&quot;https://shop.hunterirrigation.com/products/hunter-hc-flow-meter-for-hydrawise-controllers&quot;&gt;Hunter specifications&lt;/a&gt;, &lt;a href=&quot;https://www.rainbird.com/products/fg100&quot;&gt;FG100 specifications&lt;/a&gt;, &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-set-up-the-fg100-flow-sensor/&quot;&gt;Rain Bird station setup&lt;/a&gt;.&lt;/p&gt;
&lt;h2&gt;Check the pipe layout and cable route&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Hunter HC-100-FLOW.&lt;/strong&gt; Hunter lists up to 1,000 feet with shielded 18 AWG cable and offers a separate wireless communication kit. Use the Quick Start Guide on Hunter’s meter page to check the pipe layout. &lt;a href=&quot;https://shop.hunterirrigation.com/products/hunter-hc-flow-meter-for-hydrawise-controllers&quot;&gt;Hunter meter specifications and Quick Start Guide&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Rain Bird FG100.&lt;/strong&gt; The FG100 can go directly after the master valve in the same box, with no straight pipe run required. Rain Bird lists up to 500 feet on standard 18 AWG irrigation wire. It calls for shielded cable where electrical interference is likely in residential installations, though standard cable may work if kept far enough from interference sources. &lt;a href=&quot;https://www.rainbird.com/products/fg100&quot;&gt;Rain Bird installation specifications&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;EveryDrop 1004-EX.&lt;/strong&gt; Install between the backflow preventer and the irrigation valves. The meter includes a 6-inch upstream straight section. Keep the pipe full, with at least 10 psi of back pressure. Rachio specifies 18 AWG two-conductor wire, and EveryDrop recommends shielded wire. &lt;a href=&quot;https://everydropmeters.com/pages/frequently-asked-questions&quot;&gt;EveryDrop installation FAQ&lt;/a&gt;, &lt;a href=&quot;https://rachio.com/products/everydrop-flow-meter&quot;&gt;Rachio installation guidance&lt;/a&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Set up monitoring after installation&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Hydrawise.&lt;/strong&gt; Use the owner’s manual linked on Hunter’s meter page to configure the sensor. Hydrawise reports flow by station and can send alerts for high, low, or unscheduled flow. &lt;a href=&quot;https://shop.hunterirrigation.com/products/hunter-hc-flow-meter-for-hydrawise-controllers&quot;&gt;Hunter manual and flow reporting&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Rain Bird ESP-ME3.&lt;/strong&gt; Turn the dial to &lt;strong&gt;Flow Sensor&lt;/strong&gt; and use &lt;strong&gt;+&lt;/strong&gt; or &lt;strong&gt;−&lt;/strong&gt; to select &lt;strong&gt;SENS ON&lt;/strong&gt;. The controller runs &lt;strong&gt;LEARN FLOW&lt;/strong&gt; to establish each station&apos;s expected flow. The ESP-ME3 can raise an alarm and suspend automatic watering at the affected station when flow is too high or too low. Remote monitoring and advanced flow settings in the Rain Bird app use the LNK2 module. &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-set-up-the-fg100-flow-sensor/&quot;&gt;Rain Bird setup&lt;/a&gt;, &lt;a href=&quot;https://wifi.rainbird.com/articles/how-does-flow-detection-work/&quot;&gt;Rain Bird flow detection&lt;/a&gt;, &lt;a href=&quot;https://www.rainbird.com/products/fg100&quot;&gt;Rain Bird app requirements&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Rachio with EveryDrop.&lt;/strong&gt; Add the wired meter as a controller accessory in the Rachio app and calibrate your zones. After calibration, the app can report zone water use and alert you to abnormal flow. Rachio also offers automatic shutoff for severe leaks. &lt;a href=&quot;https://rachio.com/products/everydrop-flow-meter&quot;&gt;Rachio setup and flow features&lt;/a&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;em&gt;Evidence and limits.&lt;/em&gt; The comparison is based on Hunter&apos;s HC-100-FLOW and Hydrawise hardware documentation, Rain Bird&apos;s FG100 and ESP-ME3 documentation, and EveryDrop&apos;s 1004-EX and Rachio Gen 2 and Rachio 3 guidance. The published specifications and setup instructions were used without hands-on testing.&lt;/p&gt;
</content:encoded><category>flow meters</category><category>irrigation</category><category>hydrawise</category><category>rain bird</category><category>rachio</category><author>Irrigation Flow Guide Editorial</author></item><item><title>Rain Bird ESP-ME3 Flow Alerts With the FG100</title><link>https://irrigationflowguide.com/posts/rain-bird-esp-me3-fg100-flow-alerts/</link><guid isPermaLink="true">https://irrigationflowguide.com/posts/rain-bird-esp-me3-fg100-flow-alerts/</guid><description>Set up Rain Bird ESP-ME3 high- and low-flow alerts with an FG100. Learn each station&apos;s flow, set alarm thresholds, and turn on phone notifications.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Start with an installed FG100. On the ESP-ME3, switch &lt;strong&gt;Flow Sensor&lt;/strong&gt; from &lt;strong&gt;SENS OFF&lt;/strong&gt; to &lt;strong&gt;SENS ON&lt;/strong&gt; to learn the expected flow for each station. With the controller connected through LNK2, use Rain Bird 1.0 to set the high- and low-flow thresholds and enable both phone notifications. &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-set-up-the-fg100-flow-sensor/&quot;&gt;Controller setup&lt;/a&gt; · &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;App setup&lt;/a&gt; · &lt;a href=&quot;https://wifi.rainbird.com/articles/flow-notifications/&quot;&gt;Flow notifications&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Check your app and controller&lt;/h2&gt;
&lt;p&gt;Rain Bird 1.0 has a white bird on a green square icon. The ESP-ME3 displays flow alarms on its own screen even without pairing with the LNK WiFi Module and the Rain Bird app. &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-identify-which-app-i-have/&quot;&gt;Identify your app&lt;/a&gt; · &lt;a href=&quot;https://wifi.rainbird.com/articles/flow-notifications/&quot;&gt;Controller display and notifications&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For Rain Bird 2.0 onboarding, follow Rain Bird&apos;s &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-add-an-esp-me3-controller-in-the-rain-bird-2-0-app-and-update-your-lnk2-device/&quot;&gt;ESP-ME3 and LNK2 setup guide&lt;/a&gt;.&lt;/p&gt;
&lt;h2&gt;Enable the FG100 at the controller&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Turn the ESP-ME3 dial to &lt;strong&gt;Flow Sensor&lt;/strong&gt;. &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-set-up-the-fg100-flow-sensor/&quot;&gt;Controller setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Press the plus or minus button to select &lt;strong&gt;SENS ON&lt;/strong&gt;. Switching from &lt;strong&gt;SENS OFF&lt;/strong&gt; starts Learn Flow, which runs each station for 3 to 4 minutes to establish its expected flow. &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-set-up-the-fg100-flow-sensor/&quot;&gt;Controller setup&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Select the FG100 and review learned flow&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;On the ESP-ME3 screen in Rain Bird 1.0, tap the &lt;strong&gt;Controller Settings&lt;/strong&gt; icon. Expand &lt;strong&gt;Flow Sensor Settings&lt;/strong&gt; and make sure &lt;strong&gt;Flow Sensor Installed&lt;/strong&gt; is checked. &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;FG100 app setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Open &lt;strong&gt;Change Flow Settings&lt;/strong&gt; and set &lt;strong&gt;Sensor Type&lt;/strong&gt; to &lt;strong&gt;Rain Bird FG100&lt;/strong&gt;. &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;FG100 app setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;To start a learning run from the app, select &lt;strong&gt;Learn Flow&lt;/strong&gt; in &lt;strong&gt;Flow Sensor Settings&lt;/strong&gt;. The controller runs each station to establish its expected flow rate. &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;FG100 app setup&lt;/a&gt; · &lt;a href=&quot;https://wifi.rainbird.com/articles/how-does-flow-detection-work/&quot;&gt;Learn Flow overview&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Once learned rates are available, open &lt;strong&gt;Change Flow Settings&lt;/strong&gt; to view or edit them. &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;FG100 app setup&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Set the thresholds, settling time, and alarm action&lt;/h2&gt;
&lt;p&gt;Edit &lt;strong&gt;Alarm Threshold&lt;/strong&gt; in &lt;strong&gt;Change Flow Settings&lt;/strong&gt;. The defaults are 130% of learned flow for high flow and 70% for low flow. For a station with a hypothetical learned rate of 10 gallons per minute (GPM), the defaults give the thresholds below. &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;FG100 app setup&lt;/a&gt; · &lt;a href=&quot;https://wifi.rainbird.com/articles/how-does-flow-detection-work/&quot;&gt;High- and low-flow detection&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Threshold&lt;/th&gt;
&lt;th&gt;Example calculation&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;High flow&lt;/td&gt;
&lt;td&gt;10 GPM × 1.30 = 13 GPM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Low flow&lt;/td&gt;
&lt;td&gt;10 GPM × 0.70 = 7 GPM&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;Set &lt;strong&gt;Settling Time&lt;/strong&gt; from 1 to 10 minutes. The flow rate must stay at or above the high-flow threshold or below the low-flow threshold for that long before the controller issues an alarm or takes action. &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;Settling time&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Choose how the controller handles watering when a flow alarm occurs. &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;Alarm actions&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Alarm action&lt;/th&gt;
&lt;th&gt;Effect on watering&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Alarm Only&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Regular watering continues in all zones.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Alarm &amp;amp; Skip Problem Zone&lt;/strong&gt; (default)&lt;/td&gt;
&lt;td&gt;Watering is suspended for the affected zone.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Alarm &amp;amp; Skip All Zones&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Watering is suspended for all zones.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Turn on phone notifications and clear controller alarms&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;In the Rain Bird 1.0 controller settings, turn on notifications for &lt;strong&gt;High Flow Alarm&lt;/strong&gt; and &lt;strong&gt;Low Flow Alarm&lt;/strong&gt;. &lt;a href=&quot;https://wifi.rainbird.com/articles/flow-notifications/&quot;&gt;Flow notifications&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;In your phone settings, allow notifications for the Rain Bird app. &lt;a href=&quot;https://wifi.rainbird.com/articles/flow-notifications/&quot;&gt;Phone permissions&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;Tap a station&apos;s flow notification to open the app and see the controller name, zone number, and event date and time. After resolving the flow problem, press the right arrow (&lt;strong&gt;Advance&lt;/strong&gt;) while the alarm message scrolls on the ESP-ME3 to clear it. &lt;a href=&quot;https://wifi.rainbird.com/articles/flow-notifications/&quot;&gt;Alarm details and clearing&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For installation, see Rain Bird&apos;s &lt;a href=&quot;https://www.rainbird.com/products/fg100/support&quot;&gt;FG100 support page&lt;/a&gt;. For sensor options, see the Flow Sensors section of &lt;a href=&quot;https://www.rainbird.com/controller-connectivity&quot;&gt;Rain Bird Connectivity&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; Rain Bird&apos;s ESP-ME3 controller and Rain Bird 1.0 app instructions were checked on 27 November 2026. This guide is not based on hands-on testing. &lt;a href=&quot;https://wifi.rainbird.com/articles/how-to-set-up-the-fg100-flow-sensor/&quot;&gt;Controller instructions&lt;/a&gt; · &lt;a href=&quot;https://wifi.rainbird.com/articles/fg100-setup-in-the-rain-bird-app/&quot;&gt;Rain Bird 1.0 instructions&lt;/a&gt;&lt;/p&gt;
</content:encoded><category>rain-bird</category><category>esp-me3</category><category>fg100</category><category>flow-alerts</category><author>Irrigation Flow Guide Editorial</author></item><item><title>Pipe Diameter, Straight-Run Length and K-Factor Calibration</title><link>https://irrigationflowguide.com/posts/pipe-diameter-straight-run-length-k-factor-calibration/</link><guid isPermaLink="true">https://irrigationflowguide.com/posts/pipe-diameter-straight-run-length-k-factor-calibration/</guid><description>Match a pulse flow sensor to your pipe diameter, calculate upstream and downstream straight-run lengths, and check its K-factor using a known volume.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;For a pulse-output irrigation flow sensor, match the meter and fitting to the pipe dimensions called for by the manufacturer. Leave the specified straight pipe on both sides of the meter. Use the published K-factor, then field-check a pulses-per-volume setting by dividing the number of pulses by the volume collected during the same run. &lt;a href=&quot;https://www.blue-white.com/help-center/f-2000/f-2000-installation/&quot;&gt;Blue-White installation guide&lt;/a&gt; · &lt;a href=&quot;https://seametrics.com/support-resources/k-factor-calculator/&quot;&gt;Seametrics K-factor calculator&lt;/a&gt; · &lt;a href=&quot;https://aw-lake.com/news-blog-resources/press-releases/how-to-perform-a-beaker-test-to-determine-a-flow-meter-k-factor/&quot;&gt;AW-Lake field procedure&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Match the pipe and fitting&lt;/h2&gt;
&lt;p&gt;Start with the meter model and fitting type. For a Blue-White F-2000 saddle, record the pipe schedule or metric pressure class and check both diameters against the fitting requirements. Blue-White specifies the outside diameter for the saddle to seal and the inside diameter for meter accuracy. &lt;a href=&quot;https://www.blue-white.com/help-center/f-2000/f-2000-installation/&quot;&gt;Blue-White installation guide&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For a supported Seametrics configuration, select the meter and installation type. Enter the fitting material and size where the calculator asks for them. Where the calculator asks for pipe dimensions, enter the outside diameter and wall thickness in the chosen units. &lt;a href=&quot;https://seametrics.com/support-resources/k-factor-calculator/&quot;&gt;Seametrics K-factor calculator&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Lay out the upstream and downstream runs&lt;/h2&gt;
&lt;p&gt;Read the model&apos;s upstream and downstream multipliers separately. Multiply each by the diameter specified for that model. For the Blue-White F-2000, measure the straight pipe to the inlet on the upstream side and from the outlet on the downstream side. Keep the meter as far as possible from disturbances such as elbows, tees and valves. &lt;a href=&quot;https://www.blue-white.com/help-center/f-2000/f-2000-installation/&quot;&gt;Blue-White installation guide&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Installation&lt;/th&gt;
&lt;th&gt;Straight pipe before the inlet&lt;/th&gt;
&lt;th&gt;Straight pipe after the outlet&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Blue-White F-2000&lt;/td&gt;
&lt;td&gt;At least 10 × pipe inside diameter&lt;/td&gt;
&lt;td&gt;At least 5 × pipe inside diameter&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;For the F-2000, the required length depends on the disturbance. Blue-White says the straight run can need up to 50 inside diameters when the meter is downstream of control valves or pumps. The F-2000 also requires a full pipe. &lt;a href=&quot;https://www.blue-white.com/help-center/f-2000/f-2000-installation/&quot;&gt;Blue-White installation guide&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Enter the published K-factor&lt;/h2&gt;
&lt;p&gt;For a controller that takes pulses per unit of volume, use the published value for the installed configuration and match the volume units. Seametrics&apos; calculator can return pulses per gallon, liter or cubic meter. A setting expressed as volume per pulse uses the reciprocal of the pulses-per-volume value in the same volume unit. &lt;a href=&quot;https://seametrics.com/support-resources/k-factor-calculator/&quot;&gt;Seametrics K-factor calculator&lt;/a&gt; · &lt;a href=&quot;https://aw-lake.com/news-blog-resources/press-releases/how-to-perform-a-beaker-test-to-determine-a-flow-meter-k-factor/&quot;&gt;AW-Lake field procedure&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Field-check with a known volume&lt;/h2&gt;
&lt;p&gt;Use a calibrated collection vessel and a display or counter that can read the raw pulses. Verify the meter&apos;s required piping conditions before the check. If the setup needs changes, isolate and depressurize the equipment before modifying the piping. &lt;a href=&quot;https://aw-lake.com/news-blog-resources/press-releases/how-to-perform-a-beaker-test-to-determine-a-flow-meter-k-factor/&quot;&gt;AW-Lake field procedure&lt;/a&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Purge air from the line and let the water flow stabilize near the rate the meter normally sees. &lt;a href=&quot;https://aw-lake.com/news-blog-resources/press-releases/how-to-perform-a-beaker-test-to-determine-a-flow-meter-k-factor/&quot;&gt;AW-Lake field procedure&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Record the starting raw pulse count. Capture all water discharged during the collection interval, stop the flow and record the ending count and actual volume. &lt;a href=&quot;https://aw-lake.com/news-blog-resources/press-releases/how-to-perform-a-beaker-test-to-determine-a-flow-meter-k-factor/&quot;&gt;AW-Lake field procedure&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Subtract the starting count from the ending count and divide by the collected volume. AW-Lake&apos;s example gives 22,510 − 12,450 = 10,060 pulses. For 10.00 liters, the K-factor is &lt;strong&gt;1,006 pulses per liter&lt;/strong&gt;. &lt;a href=&quot;https://aw-lake.com/news-blog-resources/press-releases/how-to-perform-a-beaker-test-to-determine-a-flow-meter-k-factor/&quot;&gt;AW-Lake field procedure&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Make at least three runs under the same flow conditions. Calculate the K-factor for each and average them. If the results are repeatable and meet the required tolerance, use the average in the units your controller expects, subject to site quality and calibration requirements. If they vary significantly, check for air, leaks, unstable flow or missed pulses before repeating the check. &lt;a href=&quot;https://aw-lake.com/news-blog-resources/press-releases/how-to-perform-a-beaker-test-to-determine-a-flow-meter-k-factor/&quot;&gt;AW-Lake field procedure&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; Checked November 27, 2026. This guide draws on the Blue-White F-2000 installation guide, the Seametrics web calculator and AW-Lake&apos;s October 13, 2026 field procedure. No field checks were performed for this article.&lt;/p&gt;
</content:encoded><category>flow sensors</category><category>pipe sizing</category><category>straight run</category><category>calibration</category><author>Irrigation Flow Guide Editorial</author></item><item><title>Best Wireless Irrigation Flow Meters Without Trenching</title><link>https://irrigationflowguide.com/posts/best-wireless-irrigation-flow-meters-cannot-trench-wire/</link><guid isPermaLink="true">https://irrigationflowguide.com/posts/best-wireless-irrigation-flow-meters-cannot-trench-wire/</guid><description>Compare Hunter, EveryDrop and Tucor wireless flow meters by controller, pipe size and radio range before you buy parts or cut into your irrigation line.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;If you cannot trench wire, pair a compatible Hydrawise controller with Hunter’s Wireless HC kit and HC Flow Meter. For a Rachio 3 with an above-ground 1-inch mainline, choose EveryDrop’s WL-1200. If you have a Hunter ACC, ACC2 or I-Core, start with the Hunter WFS. &lt;a href=&quot;https://www.hunterirrigation.com/support/hydrawise-whc-flow-system-overview-operations&quot;&gt;Hunter Wireless HC overview&lt;/a&gt;, &lt;a href=&quot;https://everydropmeters.com/products/model-wl-1200-1-irrigation-wireless-flow-meter&quot;&gt;EveryDrop product guide&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/irrigation-product/sensors/wireless-flow-sensor&quot;&gt;Hunter WFS product guide&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;These setups send readings by radio across the yard. The meter still needs a place in the pipe, and the receiver still connects locally to the controller. &lt;a href=&quot;https://www.hunterirrigation.com/support/hydrawise-whc-flow-installation&quot;&gt;Hunter Wireless HC installation&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-installing-wfs-sensor-and-fct-tee&quot;&gt;Hunter WFS installation&lt;/a&gt;, &lt;a href=&quot;https://everydropmeters.com/products/model-wl-1200-1-irrigation-wireless-flow-meter&quot;&gt;EveryDrop product guide&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Wireless irrigation flow meters by setup&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Option&lt;/th&gt;
&lt;th&gt;Controller fit&lt;/th&gt;
&lt;th&gt;Pipe and parts&lt;/th&gt;
&lt;th&gt;Published radio reach or siting requirement&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Hunter Wireless HC&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hydrawise-enabled HC, HPC, Pro-HC or HCC&lt;/td&gt;
&lt;td&gt;W-HC-FLOW transmitter and receiver kit plus a separately sold HC Flow Meter in ¾, 1, 1½ or 2 inches&lt;/td&gt;
&lt;td&gt;500 ft with line of sight. &lt;a href=&quot;https://www.hunterirrigation.com/irrigation-product/sensors/hc-flow-meter&quot;&gt;HC specs&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Hunter WFS&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ACC, ACC2, I-Core or a compatible ICC2 communication module&lt;/td&gt;
&lt;td&gt;WFS kit includes the sensor, transmitter and receiver. Order the matching FCT tee separately for 1, 1½, 2, 3 or 4 inches.&lt;/td&gt;
&lt;td&gt;Up to 500 ft with clear line of sight. &lt;a href=&quot;https://www.hunterirrigation.com/irrigation-product/sensors/wireless-flow-sensor&quot;&gt;WFS specs&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-troubleshooting&quot;&gt;range conditions&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;EveryDrop WL-1200&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rachio 3 has a documented connection. For another flow-capable controller, verify that its input accepts a UMI-200 output mode.&lt;/td&gt;
&lt;td&gt;1-inch meter, PVC unions and UMI-200 receiver are included.&lt;/td&gt;
&lt;td&gt;Published reach exceeds 500 ft with line of sight. EveryDrop recommends an above-ground sensor location. &lt;a href=&quot;https://everydropmeters.com/products/model-wl-1200-1-irrigation-wireless-flow-meter&quot;&gt;WL-1200 guide&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Tucor Wireless FLEXFlow&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Flow-capable controller with compatible flow terminals and power output for the gateway&lt;/td&gt;
&lt;td&gt;Ultrasonic meter, radio transmitter and gateway. The grooved assembly fits 1½- to 4-inch lines. Saddle options are 6, 8, 10 and 12 inches.&lt;/td&gt;
&lt;td&gt;Tucor lists up to 1 mile using optional radio equipment to extend reach. Tucor lists FLEXFlow under legacy products, so confirm availability with a distributor before planning around it. &lt;a href=&quot;https://tucor.com/wireless-flexflow/&quot;&gt;FLEXFlow specifications and ordering&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;What to check before you buy&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;&lt;strong&gt;Match the controller input and power.&lt;/strong&gt; The Wireless HC receiver runs from the controller’s 24 VAC terminals, and its transmitter takes three AA batteries. The WFS also uses a 24 V AC receiver, with three AA batteries or Hunter’s WFSLITHBATT pack for the transmitter. &lt;a href=&quot;https://www.hunterirrigation.com/support/hydrawise-whc-flow-system-overview-operations&quot;&gt;Wireless HC overview&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-specifications&quot;&gt;WFS electrical specifications&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check the receiver’s location and output.&lt;/strong&gt; The WL-1200 sensor takes two AA batteries. Put its UMI-200 indoors or in a weatherproof enclosure and power it from 24 VAC or the optional 5 VDC adapter. Match the controller’s flow input to the UMI-200’s frequency-pulse or pulse-per-gallon output. The Tucor gateway uses 24 VAC and its transmitter uses a replaceable 3.6 V lithium metal battery. &lt;a href=&quot;https://everydropmeters.com/products/model-wl-1200-1-irrigation-wireless-flow-meter&quot;&gt;EveryDrop product guide&lt;/a&gt;, &lt;a href=&quot;https://tucor.com/wireless-flexflow/&quot;&gt;FLEXFlow specifications&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Compare zone flow with the published minimum and recommended maximum.&lt;/strong&gt; If your highest-flow zone uses 1 GPM, that flow falls within the 1-inch HC-100-FLOW’s published range of 0.3 GPM minimum to 30 GPM recommended maximum. It falls below the 2 GPM minimum Hunter recommends for the highest-flow zone when using a 1-inch WFS. &lt;a href=&quot;https://www.hunterirrigation.com/irrigation-product/sensors/hc-flow-meter&quot;&gt;HC flow specifications&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-specifications&quot;&gt;WFS flow specifications&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Measure the straight pipe on both sides.&lt;/strong&gt; A 1-inch HC Flow Meter needs 10 inches upstream and 5 inches downstream. Install it horizontally with the dial up and the arrow pointing in the direction of flow. For WFS, allow at least 10 pipe diameters of straight pipe upstream and 5 downstream of the tee. Hunter calls for a master valve for overflow protection. &lt;a href=&quot;https://www.hunterirrigation.com/support/hydrawise-flow-meter-install-guide&quot;&gt;HC install guide&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-installing-wfs-sensor-and-fct-tee&quot;&gt;WFS tee installation&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Check the signal at the installation site&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;EveryDrop WL-1200.&lt;/strong&gt; Before cutting pipe, put the sensor near its proposed location with the UMI-200 connected to the controller. Check the signal strength on the receiver display. EveryDrop warns that soil, especially wet soil, weakens the signal. &lt;a href=&quot;https://everydropmeters.com/products/model-wl-1200-1-irrigation-wireless-flow-meter&quot;&gt;EveryDrop signal check&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Hunter WFS.&lt;/strong&gt; Install the receiver at the controller and take the battery-powered sensor and transmitter to the proposed location. Spin the impeller by hand. Have someone at the controller check that the receiver flashes green while the impeller turns. If the link fails, check the distance, obstructions and whether the two radio channels match. &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-installing-wfs-sensor-and-fct-tee&quot;&gt;WFS installation and site survey&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-troubleshooting&quot;&gt;WFS troubleshooting&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Tucor Wireless FLEXFlow.&lt;/strong&gt; Ask a Tucor wireless distributor to confirm the meter, gateway and any repeater needed for your site. Tucor requires a radio site survey before shipping a Wireless FLEXFlow order. &lt;a href=&quot;https://tucor.com/wireless-flexflow/&quot;&gt;Tucor ordering requirements&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Confirm the controller is receiving flow&lt;/h2&gt;
&lt;p&gt;For Wireless HC, select the installed meter model in Hydrawise. With a zone running, check for green flashes on the receiver, then open that active zone in the app and scroll to &lt;strong&gt;Water Used&lt;/strong&gt; to see accumulated flow. &lt;a href=&quot;https://www.hunterirrigation.com/support/hydrawise-flow-meter-install-guide&quot;&gt;HC software configuration&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/hydrawise-whc-flow-installation&quot;&gt;Wireless HC receiver indicators&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/hydrawise-app-water-used-flow&quot;&gt;Hydrawise Water Used display&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For Hunter WFS, select the matching FCT model at the controller. During flow, a flashing green receiver LED indicates that the receiver is getting flow data. &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-specifications&quot;&gt;WFS calibration specifications&lt;/a&gt;, &lt;a href=&quot;https://www.hunterirrigation.com/support/wfs-troubleshooting&quot;&gt;WFS receiver indicators&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For EveryDrop, run flow calibration in the controller’s app. EveryDrop describes calibration as running each zone and recording its normal flow as a baseline for detecting high or low flow. &lt;a href=&quot;https://everydropmeters.com/products/model-wl-1200-1-irrigation-wireless-flow-meter&quot;&gt;EveryDrop calibration guide&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; The U.S. Hunter HC and WFS documentation, EveryDrop WL-1200 and UMI-200 guide, and Tucor Wireless FLEXFlow specifications were checked on November 26, 2026. No installations or range tests were performed for this guide.&lt;/p&gt;
</content:encoded><category>flow meters</category><category>wireless irrigation</category><category>irrigation controllers</category><category>retrofits</category><author>Irrigation Flow Guide Editorial</author></item></channel></rss>