For a pulse-output irrigation flow sensor, match the meter and fitting to the pipe dimensions called for by the manufacturer. Leave the specified straight pipe on both sides of the meter. Use the published K-factor, then field-check a pulses-per-volume setting by dividing the number of pulses by the volume collected during the same run. Blue-White installation guide · Seametrics K-factor calculator · AW-Lake field procedure
Match the pipe and fitting
Start with the meter model and fitting type. For a Blue-White F-2000 saddle, record the pipe schedule or metric pressure class and check both diameters against the fitting requirements. Blue-White specifies the outside diameter for the saddle to seal and the inside diameter for meter accuracy. Blue-White installation guide
For a supported Seametrics configuration, select the meter and installation type. Enter the fitting material and size where the calculator asks for them. Where the calculator asks for pipe dimensions, enter the outside diameter and wall thickness in the chosen units. Seametrics K-factor calculator
Lay out the upstream and downstream runs
Read the model’s upstream and downstream multipliers separately. Multiply each by the diameter specified for that model. For the Blue-White F-2000, measure the straight pipe to the inlet on the upstream side and from the outlet on the downstream side. Keep the meter as far as possible from disturbances such as elbows, tees and valves. Blue-White installation guide
| Installation | Straight pipe before the inlet | Straight pipe after the outlet |
|---|---|---|
| Blue-White F-2000 | At least 10 × pipe inside diameter | At least 5 × pipe inside diameter |
For the F-2000, the required length depends on the disturbance. Blue-White says the straight run can need up to 50 inside diameters when the meter is downstream of control valves or pumps. The F-2000 also requires a full pipe. Blue-White installation guide
Enter the published K-factor
For a controller that takes pulses per unit of volume, use the published value for the installed configuration and match the volume units. Seametrics’ calculator can return pulses per gallon, liter or cubic meter. A setting expressed as volume per pulse uses the reciprocal of the pulses-per-volume value in the same volume unit. Seametrics K-factor calculator · AW-Lake field procedure
Field-check with a known volume
Use a calibrated collection vessel and a display or counter that can read the raw pulses. Verify the meter’s required piping conditions before the check. If the setup needs changes, isolate and depressurize the equipment before modifying the piping. AW-Lake field procedure
- Purge air from the line and let the water flow stabilize near the rate the meter normally sees. AW-Lake field procedure
- Record the starting raw pulse count. Capture all water discharged during the collection interval, stop the flow and record the ending count and actual volume. AW-Lake field procedure
- Subtract the starting count from the ending count and divide by the collected volume. AW-Lake’s example gives 22,510 − 12,450 = 10,060 pulses. For 10.00 liters, the K-factor is 1,006 pulses per liter. AW-Lake field procedure
- Make at least three runs under the same flow conditions. Calculate the K-factor for each and average them. If the results are repeatable and meet the required tolerance, use the average in the units your controller expects, subject to site quality and calibration requirements. If they vary significantly, check for air, leaks, unstable flow or missed pulses before repeating the check. AW-Lake field procedure
Evidence and limits. Checked November 27, 2026. This guide draws on the Blue-White F-2000 installation guide, the Seametrics web calculator and AW-Lake’s October 13, 2026 field procedure. No field checks were performed for this article.