Run time calculator
Work out how fast a zone puts water down (its precipitation rate) and how long it must run to apply the depth you want. Everything is worked out from the figures you type, using the exact unit conversions shown below. The results are estimates.
The formulas
US units: PR (in/h) = 96.25 × flow (GPM) ÷ area (ft²)
Where 96.25 comes from: one US gallon is 231 cubic inches. A flow of 1 GPM is 231 in³ a minute, or 231 × 60 = 13,860 in³ an hour. Spread over one square foot (144 in²), that is 13,860 ÷ 144 = 96.25 inches an hour.
Metric units: PR (mm/h) = 60 × flow (L/min) ÷ area (m²), because one litre spread over one square metre is one millimetre deep, and an hour has 60 minutes.
Run time: minutes = depth ÷ PR × 60. Each cycle is the run time divided by the number of cycles.
Unit switch: 1 in = 25.4 mm exactly, 1 ft² = 0.09290304 m² exactly, and 1 US gallon = 231 in³, which is 231 × 2.54³ ÷ 1,000 = 3.785411784 L exactly (1 L = 0.001 m³). The inch-based factors in NIST's Appendix B.8 are shown rounded, so the litre figure here is worked out from the 231 in³ definition rather than copied. When you switch units, the calculator converts from the figure you originally typed, and switching back restores it.
Calculator conventions, not physical laws: the box limits (1,000 GPM, which is 3,785.41 L/min; 1,000,000 ft², which is 92,903.04 m²; 10 in, which is 254 mm; and 12 cycles), the 24-hour cutoff for "over 24 hours", and the rounding of results (to 0.1 minute, or 0.01 minute under 1 minute, with "< 0.01" below that) are choices made for this page. Rounded figures such as the other-unit rate are shown as "about".
What the estimate assumes
- All of the zone's flow lands on the area you entered, and lands evenly. Real sprinklers and drip lines never water perfectly evenly, so some spots get less than the average and some get more.
- No water is lost to runoff, wind or evaporation.
- The flow is the zone's real running flow. A flow meter reading taken while the zone runs is a good figure to use; a sum of catalogue nozzle flows can differ from what the zone really delivers.
- The "length × width" hint assumes a rectangular wetted area. For other shapes, or for a drip zone, use whatever area you count as watered; the result is an average depth over it.
- The result is an estimate, not a measurement. For a sprinkler zone, a catch-cup check on your own lawn gives a measured rate; see the University of Minnesota Extension page below.
Sources
- Guide for the Use of the International System of Units (SI), Special Publication 811, Appendix B.8, "Factors for Units Listed Alphabetically", National Institute of Standards and Technology (NIST). Used for the inch (0.0254 m) and the square foot (0.09290304 m²). Its US gallon entry is rounded, so it does not on its own give the exact 231 in³ figure.
- "How Do You Measure Fuel at the Gas Pump?", NIST. Used for the US gallon being 231 cubic inches.
- Guide for the Use of the International System of Units (SI), Special Publication 811, Chapter 5, "Units Outside the SI", NIST. Used for 60 minutes in an hour and 1 litre = 0.001 m³.
- "Auditing home lawn irrigation systems", University of Minnesota Extension. Used for the catch-cup check on sprinkler zones.